Batch Mixing vs Proportioning Systems in Softwashing
Mark Cave breaks down the mechanics of batch mixing versus proportioning systems, highlighting why chemical delivery errors and guessing concentrations cause job failures. Learn the proper order of mixing, exact concentration formulas, and the practical trade-offs between portable trolleys and static van tanks.
Chapter 1
x
Mark Cave
Most of the time, when a softwash job goes wrong, it isn't the chemical's fault. It's the delivery. The contractor simply didn't know what strength was really hitting the wall. I'm Mark Cave from SoftWash UK, and today we're comparing batch mixing with proportioning systems.
Mark Cave
Here's where it goes wrong. You've got a tank that's half empty. You tip some more hypo in by eye, top up with water, and off you go. That next batch is a guess. Do that a few times and the concentration can swing by as much as forty percent. That's the difference between a clean wall and a damaged one.
Mark Cave
So let's start with batch mixing, because everyone should master it first. The order matters. Water in the tank first, then your concentrate, then surfactant last. Water first reduces splash risk. Surfactant last stops the tank foaming up like a bubble bath.
Mark Cave
The formula is simple. Concentrate needed equals your final tank volume, times your target strength, divided by your stock strength. So twenty litres of three percent, from fifteen percent hypo, is twenty times three, divided by fifteen. Four litres of hypo, and sixteen litres of water and surfactant. Do the sum every time. And remember, old hypo isn't fifteen percent any more. If it's sat in a hot van, your three percent might be a lot less.
Mark Cave
Now, the portable trolley. Twenty five to fifty litres, a twelve volt pump. Not glamorous, but brilliant for terraced houses, courtyards and tight rear gardens. Imagine dragging fifty metres of chemical hose down a side alley and through someone's living room. That's a trip hazard, a spill risk, and you lose pressure to friction anyway. The trade-off is volume. You'll be refilling a lot.
Mark Cave
Then the static van tank. A hundred to three hundred litres or more. The big plus is honest, uniform chemistry all the way down the hose. But think about weight. One litre is one kilo. Two hundred litres is two hundred kilos, before you count the tank itself. Then there's surge, with all that liquid sloshing when you brake. Hot vans degrade your hypo faster. And if the job finishes early, you're left with corrosive mixed waste to deal with. That's the top-up trap again. Drain it and recalculate, never top up by eye.